LightSound Lab 02 · Researcher’s guide
Researcher’s guide
For researchers and teachers who run STUDENT·RESET 1.2 with students: how the conditions differ, how to conduct a session, what each data field means and how to keep the procedure safe and ethical.
Contents
1. What the prototype is
STUDENT·RESET 1.2 is a standardised experimental tool for a 180-second light–sound pause. It supports a control group, offers four light atmospheres, and measures change in tension and tiredness separately. The program is deliberately neutral: participants are asked to breathe at their own pace, and the experimental or control condition is assigned by the study protocol, not chosen by the participant.
2. Conditions and light atmospheres
| Condition (code) | What the participant sees | Sound, if on | Default atmosphere |
|---|---|---|---|
| Noise → Silence (exam) | 75 particles of light gather towards the centre over 180 s | 174.61 / 261.63 Hz | Turquoise stillness (teal) |
| Warm pause (warm) | A still, low-brightness warm field | 136.10 / 204.15 Hz | Warm amber (amber) |
| Clear focus (focus) | Radial lines align towards the centre | 220.00 / 329.63 Hz | Forest calm (forest) |
| Control pause (control) | A calm dark screen; sound, cues and colour locked off | — | none_control |
The fourth atmosphere, Deep indigo (indigo), can be chosen for any experimental condition. The atmospheres are colours produced by a screen — mixtures of red, green and blue light — not narrow spectral lines, so no wavelengths are given. “Warm amber” contains little blue light, but not none; its real spectrum depends on the screen used. For comparable data, use the same screen, brightness and room lighting for all participants.
3. Conducting a session
- Before the study: obtain informed consent, prepare a list of participant codes and the order of conditions (for example a randomisation list), and decide how the files will be stored.
- Set the screen brightness and room lighting as fixed in your protocol; ideally use full-screen mode (F11).
- Enter the participant code (never a name), select the condition and, if the protocol allows, the atmosphere. Set sound, breathing cues and animation as the protocol requires.
- Recommended — blind assignment: press Create a participant link (condition hidden). The link opens a screen with only the code, the two ratings and the start button; the condition is not named on screen or readable in the address. Prepare one link per participant (with the code filled in) or one per condition, and open it on the participant’s screen.
- The participant rates tension and tiredness now (0–10). Both fields start empty to avoid anchoring.
- Press Start 180 seconds. The participant may pause or end the session at any time.
- After the session the participant rates tension and tiredness again, plus comfort and what they noticed; the reason for ending early and a comment are optional.
- Download the CSV (and, if you wish, the JSON) file, then press New session for the next participant.
4. Data fields
| Field | Meaning and values |
|---|---|
timestamp | Start of the session, ISO 8601, UTC |
app_version | Program version, e.g. 1.2.1 |
lang | Interface language: uk, en, hu |
setup_locked | true if the session was opened from a participant link (condition hidden) |
participant_id | Participant code; ANON if left empty |
mode | exam, warm, focus, control |
chosen_spectrum | teal, amber, forest, indigo; none_control in the control condition |
stress_pre, fatigue_pre | Tension and tiredness before, 0–10 |
sound_enabled, breath_cues, motion_enabled | Settings at the start: true / false |
volume_setting | Volume slider at the start, 0–50 |
duration_target_sec, duration_actual_sec | 180, and the time actually spent (pauses excluded) |
sound_changed_during | true if the participant switched the sound on or off during the session |
completion_rate, completed_full | Share of the 180 s completed (0–1); true if not ended early |
stress_post, fatigue_post | Tension and tiredness after, 0–10 |
stress_delta, fatigue_delta | After minus before; a negative value means a decrease |
comfort | comfortable, neutral, uncomfortable |
reported_effect | easier_breathing, less_eye_strain, fewer_intrusive_thoughts, more_clarity, no_change, less_comfortable, other |
early_stop_reason | discomfort, no_time, technical, other; empty if not stated |
comment | Free text, up to 500 characters, no personal data |
Answers are stored as codes, not as text, so that data collected in Ukrainian, English and Hungarian can be combined directly.
5. Analysis
- Each session produces one file with one row; all files share the same header. Combine them, for example with Excel Power Query (Get Data → From Folder), R or Python.
- Compare stress_delta and fatigue_delta between conditions, with the control pause as the reference.
- Decide in advance how to treat sessions with completed_full = false, and report it.
- Self-ratings are subjective; small samples call for caution in interpretation.
6. Sensory safety and ethics
- The light field pulses at 0.1 Hz (one cycle every 10 s) — far below the flash threshold of WCAG 2.3 (three flashes per second). There are no flashes or sudden changes of brightness.
- Sound is off by default; at the maximum slider position (50 %) the program’s output gain is limited to 0.075.
- The tool is presented as an experimental pause, not a medical treatment. Participants can pause or end at any moment, and early ending is recorded without judgement.
- Use codes, never names. The program sends nothing to a server: files exist only where they are downloaded.
- People with photosensitive conditions or who feel unwell should not take part.
7. If something does not work
- No sound: tick “Turn on sound” before starting, or press the Sound button during the session; browsers start audio only after a click.
- Files do not download: allow downloads for this site in the browser.
- Distracting interface: switch to full-screen mode (F11) before starting.
8. Changes in version 1.2.1
- Fixed an error that prevented the program from running.
- Full interface in Ukrainian, English and Hungarian; the language is recorded in the data (lang).
- Answers are stored as language-independent codes; the program version is recorded (app_version).
- Participant links with the condition hidden, for blind assignment (setup_locked); a change of sound during the session is recorded (sound_changed_during).
- The colour atmospheres are described without wavelengths, since a screen cannot produce single wavelengths.
- The visual and sound parameters of version 1.2 are unchanged.
← Back to the STUDENT·RESET page
A research prototype of the SMART City Institute, UzhNU · VGORAY / LightSound project
Concept and direction: Daniel A. Freedman — stage director, founder of the Lux Aeterna Light and Music Theatre
Published on LightSound — a digital ecosystem-school for interdisciplinary research
Scientific and Educational Institute of Multidisciplinary Research “SMART City”, Uzhhorod National University · svitlozvuk.freedanman.com · 2026