LightSound · home ← Map

LightSound Lab 02 · Researcher’s guide

Researcher’s guide

For researchers and teachers who run STUDENT·RESET 1.2 with students: how the conditions differ, how to conduct a session, what each data field means and how to keep the procedure safe and ethical.

Open the pilot →

Contents

1. What the prototype is

STUDENT·RESET 1.2 is a standardised experimental tool for a 180-second light–sound pause. It supports a control group, offers four light atmospheres, and measures change in tension and tiredness separately. The program is deliberately neutral: participants are asked to breathe at their own pace, and the experimental or control condition is assigned by the study protocol, not chosen by the participant.

2. Conditions and light atmospheres

Condition (code)What the participant seesSound, if onDefault atmosphere
Noise → Silence (exam)75 particles of light gather towards the centre over 180 s174.61 / 261.63 HzTurquoise stillness (teal)
Warm pause (warm)A still, low-brightness warm field136.10 / 204.15 HzWarm amber (amber)
Clear focus (focus)Radial lines align towards the centre220.00 / 329.63 HzForest calm (forest)
Control pause (control)A calm dark screen; sound, cues and colour locked off—none_control

The fourth atmosphere, Deep indigo (indigo), can be chosen for any experimental condition. The atmospheres are colours produced by a screen — mixtures of red, green and blue light — not narrow spectral lines, so no wavelengths are given. “Warm amber” contains little blue light, but not none; its real spectrum depends on the screen used. For comparable data, use the same screen, brightness and room lighting for all participants.

3. Conducting a session

  1. Before the study: obtain informed consent, prepare a list of participant codes and the order of conditions (for example a randomisation list), and decide how the files will be stored.
  2. Set the screen brightness and room lighting as fixed in your protocol; ideally use full-screen mode (F11).
  3. Enter the participant code (never a name), select the condition and, if the protocol allows, the atmosphere. Set sound, breathing cues and animation as the protocol requires.
  4. Recommended — blind assignment: press Create a participant link (condition hidden). The link opens a screen with only the code, the two ratings and the start button; the condition is not named on screen or readable in the address. Prepare one link per participant (with the code filled in) or one per condition, and open it on the participant’s screen.
  5. The participant rates tension and tiredness now (0–10). Both fields start empty to avoid anchoring.
  6. Press Start 180 seconds. The participant may pause or end the session at any time.
  7. After the session the participant rates tension and tiredness again, plus comfort and what they noticed; the reason for ending early and a comment are optional.
  8. Download the CSV (and, if you wish, the JSON) file, then press New session for the next participant.

4. Data fields

FieldMeaning and values
timestampStart of the session, ISO 8601, UTC
app_versionProgram version, e.g. 1.2.1
langInterface language: uk, en, hu
setup_lockedtrue if the session was opened from a participant link (condition hidden)
participant_idParticipant code; ANON if left empty
modeexam, warm, focus, control
chosen_spectrumteal, amber, forest, indigo; none_control in the control condition
stress_pre, fatigue_preTension and tiredness before, 0–10
sound_enabled, breath_cues, motion_enabledSettings at the start: true / false
volume_settingVolume slider at the start, 0–50
duration_target_sec, duration_actual_sec180, and the time actually spent (pauses excluded)
sound_changed_duringtrue if the participant switched the sound on or off during the session
completion_rate, completed_fullShare of the 180 s completed (0–1); true if not ended early
stress_post, fatigue_postTension and tiredness after, 0–10
stress_delta, fatigue_deltaAfter minus before; a negative value means a decrease
comfortcomfortable, neutral, uncomfortable
reported_effecteasier_breathing, less_eye_strain, fewer_intrusive_thoughts, more_clarity, no_change, less_comfortable, other
early_stop_reasondiscomfort, no_time, technical, other; empty if not stated
commentFree text, up to 500 characters, no personal data

Answers are stored as codes, not as text, so that data collected in Ukrainian, English and Hungarian can be combined directly.

5. Analysis

6. Sensory safety and ethics

7. If something does not work

8. Changes in version 1.2.1

← Back to the STUDENT·RESET page

A research prototype of the SMART City Institute, UzhNU · VGORAY / LightSound project
Concept and direction: Daniel A. Freedman — stage director, founder of the Lux Aeterna Light and Music Theatre
Published on LightSound — a digital ecosystem-school for interdisciplinary research
Scientific and Educational Institute of Multidisciplinary Research “SMART City”, Uzhhorod National University · svitlozvuk.freedanman.com · 2026