LightSound · home ← Map

LightSound Lab 06 · Guide

Guide

For students and teachers of lighting design, scenography, architecture, photography and film: what the laboratory shows, how to read its numbers and how to complete and hand in the practical task.

Open the laboratory →

Contents

1. What the laboratory is for

LIGHT·VOLUME / BEAM LAB is a trainer of stage and architectural light in volume. Students place four fixtures — key, fill, back and cyclorama — around an object and see how the angle of incidence, the beam angle and the strength of each light shape the volume, the shadow and the separation from the backdrop.

At the same time the laboratory calculates distance, pool size, luminous intensity, illuminance and the key-to-fill contrast, so that the artistic decision and its measurable result can be discussed together.

2. The screen

Left panel

Centre — the stage

Right panel

3. A session step by step (20–30 minutes)

  1. Look at the classic scheme. Press Classic three-point. Note the contrast above the stage, the direction of the shadow and the rim of back light.
  2. Study the key light. Select it, lower and raise it with Z, widen and narrow the beam. Notice that a wider beam spreads the same flux over a larger area, so the illuminance falls; a higher position lengthens the distance and shortens the shadow.
  3. Balance the fill. Change the fill dimmer or its position until the contrast reads 3 : 1 or 4 : 1. Compare the result with Drama / chiaroscuro.
  4. Separate the object. Adjust the back light so that its rim outlines the object against the dark backdrop, then add colour to the cyclorama if the scene needs it.
  5. Save the passport. Press Save lighting passport (PNG), write your name and group on it and add two or three sentences explaining your choices.

4. The formulae

5. For teachers

6. A methodological note

The model is simplified for teaching: light is even within the beam angle with no optical losses, the object’s centre is 1 m high, and beams, pools and shadows are drawn schematically. Real fixtures have photometric curves, field and beam angles, and lens losses; use manufacturers’ data for real projects.

7. Version 1.0

← Back to the LIGHT·VOLUME page

LightSound project
Concept and direction: Daniel A. Freedman — stage director, founder of the Lux Aeterna Light and Music Theatre
Published on LightSound — a digital ecosystem-school for interdisciplinary research
Scientific and Educational Institute of Multidisciplinary Research “SMART City”, Uzhhorod National University · svitlozvuk.freedanman.com · 2026