LightSound Lab 06 · Guide
Guide
For students and teachers of lighting design, scenography, architecture, photography and film: what the laboratory shows, how to read its numbers and how to complete and hand in the practical task.
Contents
1. What the laboratory is for
LIGHT·VOLUME / BEAM LAB is a trainer of stage and architectural light in volume. Students place four fixtures — key, fill, back and cyclorama — around an object and see how the angle of incidence, the beam angle and the strength of each light shape the volume, the shadow and the separation from the backdrop.
At the same time the laboratory calculates distance, pool size, luminous intensity, illuminance and the key-to-fill contrast, so that the artistic decision and its measurable result can be discussed together.
2. The screen
Left panel
- 01 / Lighting schemes: Classic three-point (about 3 : 1), Drama / chiaroscuro (about 10 : 1), Rembrandt 45° (about 4 : 1) and Backlit silhouette.
- 02 / Fixtures on stage: select a fixture in the list or on the stage; the list shows its dimmer and illuminance.
- 03 / Stage environment: the lit object, haze density (how visible the beams are) and ambient light.
- Practical task and links to this guide.
Centre — the stage
- Drag a fixture with the mouse or a finger; with the stage selected, the arrow keys move the chosen fixture (Shift for larger steps).
- Above the stage, the Key : Fill contrast compares the illuminance of the key and fill lights.
- Beam in haze and Grid switch the beams and the floor grid on and off.
- The view is schematic: a fixture’s position on the canvas sets its distance from the object; its height is set by the Z slider.
Right panel
- 04 / Optics: Profile / Spot (hard edge), Fresnel / Wash (soft spread) or Beam (narrow); dimmer, beam angle (4°–65°), hanging height (1.2–6 m) and colour temperature (2200–6500 K) or an RGB filter.
- 05 / Photometry at the object: distance d, pool diameter, luminous intensity I, illuminance perpendicular to the beam and on the horizontal, angle of incidence, shadow length and the total illuminance on the horizontal from key, fill and back.
3. A session step by step (20–30 minutes)
- Look at the classic scheme. Press Classic three-point. Note the contrast above the stage, the direction of the shadow and the rim of back light.
- Study the key light. Select it, lower and raise it with Z, widen and narrow the beam. Notice that a wider beam spreads the same flux over a larger area, so the illuminance falls; a higher position lengthens the distance and shortens the shadow.
- Balance the fill. Change the fill dimmer or its position until the contrast reads 3 : 1 or 4 : 1. Compare the result with Drama / chiaroscuro.
- Separate the object. Adjust the back light so that its rim outlines the object against the dark backdrop, then add colour to the cyclorama if the scene needs it.
- Save the passport. Press Save lighting passport (PNG), write your name and group on it and add two or three sentences explaining your choices.
4. The formulae
- Luminous intensity: I = Φ / Ω, where Φ is the luminous flux of the fixture (multiplied by the dimmer) and Ω = 2π(1 − cos(β/2)) the solid angle of a beam of angle β.
- Illuminance perpendicular to the beam: E⊥ = I / d² — the inverse-square law: twice the distance, a quarter of the illuminance.
- Illuminance on a horizontal surface: E = I·cos θ / d², where θ is the angle between the beam and the vertical.
- Pool diameter: D = 2·d·tan(β/2), measured across the beam axis.
- Shadow length relative to the object’s height = horizontal distance / height of the fixture above the object’s centre.
- Contrast Key : Fill = E⊥ of the key light / E⊥ of the fill light.
5. For teachers
- A basic task: reach 3 : 1 and 4 : 1 contrasts on the same object and explain the difference in mood; a second task: build a silhouette and a Rembrandt scheme from the classic one.
- Ask students to predict a number before moving a fixture (for example, what happens to the illuminance if the distance doubles), then check it.
- Compare passports side by side: the table makes every decision visible — type of optics, angle, height, dimmer and colour.
- Combine with Lab 03 LIGHT ACTOR: first understand light in volume here, then compose light in time there.
6. A methodological note
The model is simplified for teaching: light is even within the beam angle with no optical losses, the object’s centre is 1 m high, and beams, pools and shadows are drawn schematically. Real fixtures have photometric curves, field and beam angles, and lens losses; use manufacturers’ data for real projects.
7. Version 1.0
- Full interface in Ukrainian, English and Hungarian.
- Illuminance on the horizontal calculated with the cosine law (E = I·cos θ / d²) as well as perpendicular to the beam.
- Colour temperature of white drawn along the black-body curve.
- A lighting passport with a table of every fixture; keyboard and touch-screen control.
← Back to the LIGHT·VOLUME page
LightSound project
Concept and direction: Daniel A. Freedman — stage director, founder of the Lux Aeterna Light and Music Theatre
Published on LightSound — a digital ecosystem-school for interdisciplinary research
Scientific and Educational Institute of Multidisciplinary Research “SMART City”, Uzhhorod National University · svitlozvuk.freedanman.com · 2026