LightSound Lab 07 · Guide
Guide
For students and teachers of lighting design, architecture and heritage conservation: what the laboratory calculates, how to read its indicators and how to complete the practical tasks.
Contents
1. Purpose
The laboratory teaches how to design expressive, inclusive and environmentally responsible night lighting for façades, historic monuments and urban sculpture. It combines the artistic modelling of light and shade with engineering photometry, the reflectance of materials and the international limits on obtrusive light.
Every change of the luminaire is immediately reflected in the night scene, in a section of the beam and in five indicators, so that the designer sees both the image and its consequences: how bright the surface is, how much light escapes into the sky and whether passers-by are dazzled.
2. The screen
Left panel
- 1. Object, material and zone: historic façade (12 m), classical portico (9 m), park sculpture (4.5 m) or urban arch over water (6 m); travertine (ρ = 0.65), white plaster (ρ = 0.75), terracotta brick (ρ = 0.25) or patinated bronze (ρ = 0.15); environmental zone E1–E4.
- 2. Technique: Grazing — the luminaire close to the wall, light skimming the relief; Flood — from a distance, even and flat; Accent — a narrow beam with framing optics that follows the outline.
- 3. Luminaire and beam: setback d, aiming angle θ, beam angle β, flux Φ, framing optics, colour temperature and a purely visual backlight of the background. A hint under the colour temperature suggests warm or neutral white for each material.
- 4. Code: a group or participant code, without names.
Centre
- Night scene: the object as it would look at night; the stars fade as more light escapes into the sky.
- Section: luminaire, beam and object seen from the side. Light passing over the top is shown in red; a red figure marks a pedestrian whose eyes are in the beam.
- Five indicators with coloured verdicts against the chosen zone, and the buttons for the passport and the data.
3. A session step by step (15–20 minutes)
- Identify yourself. Enter a group code (for example UZHNU-MBG-01) without any personal data.
- Choose the object, material and zone. Historic centres are usually zone E3 or E4; parks on the edge of a town may be E2.
- Compare the three techniques. Press Grazing, Flood and Accent in turn and note how luminance, uniformity, sky light and glare change.
- Fine-tune. Adjust setback, aiming angle, beam, flux and colour temperature until luminance, sky light and glare are green. Use framing optics when the beam is wider than the object.
- Save and hand in. Press Save lighting passport (PNG) and Save data (JSON) and hand both to the teacher with two or three sentences about your choices.
4. The indicators and their limits
- Average illuminance E = the flux reaching the object divided by the lit area (lx). The note below it shows what share of the flux actually reaches the object.
- Luminance L = E·ρ / π (cd/m²) — what the eye perceives. CIE 150 limits the average luminance of a building façade to 5 cd/m² in zone E2, 10 in E3 and 25 in E4; in zone E1 façades should not be lit. Below 40 % of the limit the object reads weakly.
- Uniformity Emin / Eavg along the height of the object. Grazing light is deliberately uneven — it reveals relief; floodlighting is more even. This indicator is descriptive, not a pass or fail.
- Direct light into the sky — the share of the flux that passes over or beside the object. The limits follow the upward light ratio of CIE 150: 0 % in E1, 2.5 % in E2, 5 % in E3 and 15 % in E4.
- Intensity towards a pedestrian at an eye height of 1.6 m on a path between the luminaire and the object (at least 1.5 m from the luminaire). CIE 150 limits the intensity in such directions to 2,500 cd in E1, 7,500 in E2, 10,000 in E3 and 25,000 in E4.
- Colour temperature: 2200–3000 K for brick, bronze and warm stone; 3000–4000 K for light stone and plaster. Cold light on warm materials makes them look grey.
5. Three practical tasks
- Task A — a historic brick façade (zone E3). Terracotta brick, ρ = 0.25. Reach a luminance of 5–10 cd/m² with warm grazing light (2700 K), with direct light into the sky no higher than 5 % and no glare.
- Task B — a bronze park sculpture (zone E3). Patinated bronze, ρ = 0.15. Model the volume with an accent beam of 12°–16° and framing optics; luminance 4–10 cd/m², no light into the sky and no glare. Use the background backlight for the silhouette.
- Task C — a travertine portico (zone E3). Travertine, ρ = 0.65. Avoid over-lighting (L ≤ 10 cd/m²), keep sky light within 5 % and the intensity towards pedestrians within 10,000 cd, and describe how light and shade separate the columns from the recess.
- For each task, hand in the passport (PNG), the data (JSON) and a short explanation; compare solutions side by side in class.
6. A methodological note
The model is simplified for teaching: one luminaire on the ground with an even beam (I = Φ / Ω), a diffuse surface (L = E·ρ / π) and a two-dimensional section that takes the width of the beam into account; framing optics are modelled with a 30 % loss. Reflected light and the light of streets and windows are not included. The limits are those of CIE 150:2017 for the period before curfew, as reproduced in the guidance of the Institution of Lighting Professionals (GN01/21). Real projects are calculated from manufacturers’ photometric files.
7. Version 1.0
- Environmental zones E1–E4 with the luminance, upward-light and intensity limits of CIE 150.
- Geometric calculation of the flux reaching the object, of the lit area and of the light passing into the sky.
- Glare checked at a pedestrian’s eye height; framing optics; colour-temperature hints for each material.
- Section diagram, lighting passport (PNG) and data file (JSON); full interface in Ukrainian, English and Hungarian.
← Back to the FACADE·LIGHT page
LightSound project
Concept and direction: Daniel A. Freedman — stage director, founder of the Lux Aeterna Light and Music Theatre
Published on LightSound — a digital ecosystem-school for interdisciplinary research
Scientific and Educational Institute of Multidisciplinary Research “SMART City”, Uzhhorod National University · svitlozvuk.freedanman.com · 2026